Thursday, October 15, 2026

EXTRA COPY — ECG Blog #554: What is Unusual Here? — EXTRA COPY


The ECG in Figure-1 was obtained as part of an assessment for "operative clearance" for an orthopedic procedure. The patient is an older woman with known coronary disease. She was hemodynamically stable and asymptomatic in association with this ECG. 



QUESTIONS:

  • Should the patient be cleared for her orthopedic procedure?
  • What is the rhythm? 

Figure-1: The initial  ECG in today's case.



What is the Rhythm in Figure-1?

As always — I favor beginning my assessment of any 12-lead ECG by taking a quick look at the rhythm, using the P’s, Q’s, 3R Approach ( = “Watch your Ps, Qs and the 3 Rs” — as reviewed in ECG Blog #185). 

  • To emphasize — Although I always consider each of the 5 parameters in the Ps,Qs,3Rs — I vary the sequence in which I assess these parameters, depending on which parameter(s) is easiest to assess in the tracing I am looking at.


Applying this approach to the long lead II rhythm strip in Figure-1 — I noted the following:

  • The QRS is narrow in all 12 leads ( ==> the rhythm is supraventricular).
  • Although at 1st glance the rhythm appears to be Regular — on closer inspection, the R-R interval varies slightly from one beat to the next. 
  • PEARL #1: The most time-efficient way to assess complex arrhythmias is with use of calipers. For example, in today’s rhythm — it literally takes no more than seconds when using calipers to establish in Figure-1 that there is a slight irregularity of the rhythm throughout the tracing.
  • PEARL #2: The reality is that if you do not use calipers — You simply will not be able to figure out the etiology of complex arrhythmias.

  • Since the rhythm in Figure-1 is irregular — the Rate will vary (It appears that the average ventricular rate is ~60/minute).
  • P waves are present. That said — it is difficult to discern if the atrial rhythm is regular, and whether some (or any) P waves are conducting (ie, It’s difficult to tell if P waves are Related to neighboring QRS complexes — since the PR interval appears to be constantly changing).


Impression: The “good news” regarding today’s rhythm — is that we are told this older woman is hemodynamically stable and asymptomatic in association with this somewhat irregular rhythm — and that the average ventricular rate is not overly slow.

  • The above said — this is indeed a challenging rhythm that requires closer inspection to understand what is going on (which I'll address in a moment below).



What about the 12-lead ECG?

Leaving further assessment of the rhythm for a moment — I noted the following findings on the 12-lead ECG in Figure-1:

  • The frontal plane axis is markedly rightward (There is predominant negativity in the tiny QRS complex seen in lead I — in association with an all positive QRS in lead aVF). Potentially this is consistent with LPHB (Left Posterior HemiBlock) — vs RAD (Right Axis Deviation) from pure axis deviation without underlying conduction system disease.
  • The QTc interval appears to be normal.
  • There may be U waves (ie, in leads V4,V5).
  • No chamber enlargement.
  • Transition (where the R wave becomes taller than the S wave is deep) — is slightly delayed to between leads V4-to-V5. That said — infarction Q waves are absent because a tiny r wave appears to be present in leads I and aVL — and small r waves are clearly seen in leads V2 and V3.
  • Impression: The frontal plane axis is markedly rightward and there is diffuse, nonspecific ST-T wave flattening — but no suggestion of any acute changes.

============================


A closer LOOK at the Rhythm ...

To facilitate focusing on the rhythm — I’ve isolated the long lead II rhythm strip in Figure-2.

  • Regarding the rhythm — What do YOU think is going on?


Figure-2: Focusing on the long lead II rhythm strip.

============================

PEARL #3: I’ve found the simple step of numbering the beats and labeling P waves — to be surprisingly helpful in facilitating recognition of complex arrhythmia mechanisms.

  • Using calipers increases accuracy and expedites the process of rhythm assessment. 
  • Begin by looking for a place in the long lead rhythm strip where you can clearly see at least 2 consecutive P waves.
  • Then set you calipers to this P-P interval — and see if you can “walk out” where the P waves fall, including those that are partially (or totally) hidden by QRS complexes or ST-T waves on the rest of the rhythm strip. (I've done this with the RED arrows that I've added in Figure-3). The slight irregularity of sinus P waves is consistent with sinus arrhythmia.


Figure-3: RED arrows highlight the presence of an underlying sinus arrhythmia in today's tracing. 


QUESTIONS:
As you look at the rhythm in Figure-3 — Consider the following:
  • Are any of the RED arrow P waves conducting? If so — Which P waves do you think are conducting in Figure-3?
  • Is there some form of AV block? If so — Is it a "high-degree" form of AV block?
  • Why is the ventricular rhythm irregular?
============================

PEARL #4: For almost all complex arrhythmias about which I find myself asking the above questions — the KEY clues to the rhythm are almost always forthcoming by considering the following PEARLS:

  • If I see PR intervals that "repeat" — this suggests that those beats with equal PR intervals are being conducted.
  • Junctional "escape" beats tend to manifest an intrinsic heart rate between 40-60/minute in adults (slightly faster in children). Consecutive junctional "escape" beats tend to be preceeded by a similar R-R interval (because a junctional escape rhythm tends to be regular).
  • If QRS complexes clearly occur earlier-than-expected — this suggests that the reason these QRS complexes occur early, is that these beats are conducted.
  • In order to demonstrate that some form of AV block is present — We need to see on-time P waves that fail to conduct.
  • Identifying 3rd-degree ( = complete) AV block is usually easy — because the R-R interval tends to be regular (or at least almost regular) — and on-time P waves continue throughout the tracing, but these on-time P waves fail to conduct despite having more than adequate opportunity to do so.
  • If there is AV block with one or more non-conducted on-time P waves — and we have ruled out 3rd-degree AV block — then we are dealing with one of the 3 types of 2nd-degree AV block (ie, Mobitz Type I, Mobitz Type II or 2:1 AV block which could be the result of either Mobitz I or Mobitz II — as reviewed in ECG Blog #344). Of the types of 2nd-degree AV block — Mobitz Type I ( = AV Wenckebach) is by far the most common form (especially if the QRS complex is narrow).
  • In order to demonstrate a "high-grade" form of 2nd-degree AV block — We need to see consecutive on-time P waves for which at least 1 of these P waves fails to conduct despite having adequate opportunity to conduct (ie, An on-time P wave that occurs right next to a QRS complex is unlikely to have had "adequate opportunity" to conduct).

============================  

I measured the intervals ...
What is unusual about today's arrhythmia — is that the above KEY clues do not consistently work. In order to fully appreciate this — I had to precisely measure all R-R and PR intervals. Using a caliper-measurement tool — I have done this in the lower panel of Figure-4.


Figure-4: I measured all R-R and PR intervals in today's rhythm.


Breaking Down Figure-4:
  • Looking at the lower panel in Figure-4 — there are slight-but-significant differences in the R-R interval between each of the beats in today's rhythm (ie, 1.129 sec. vs 1.267 sec. vs 1.105 sec., etc.). As a result — We have no idea as to what the "expected" R-R interval is. (NOTE: We have already essentially ruled out complete AV block — because the ventricular rhythm in Figure-4 is too irregular).
  • I've reproduced Figure-3 in the upper panel of Figure-4. Looking at this upper panel — I thought the PR intervals before beats #2,4,6 and 9 looked similar. In addition — the R-R intervals preceding each of these beats look shorter than the longest R-R interval (which is the R-R interval between beats #2-3). As a result — I thought it likely that the P waves preceeding these 4 beats were probably all being conducted to the ventricles.
  • The above said — the precise PR interval measurements for beats #2,4,6,9 that are shown in the lower panel of Figure-4 reveal a subtle-but-significant difference in the PR intervals of beats #2, 4 and 6 (ie, of 0.241 sec. vs 0.265 sec. vs 0.218 second). If the P waves preceding these 3 beats are all conducting — then they are doing so with different PR intervals.

  • In Summary so Far: I count a total of 12 on-time P waves in Figure-4. There are 9 QRS complexes. This means that there are more P waves than QRS complexes — and because all P waves are "on time" — this means that at least 3 on time P waves are not conducted ==> Some form of 2nd-degree AV block is present.
    • Common Things are Common: As stated above in PEARL #4, of the 3 possible forms of 2nd-degree AV Block — Mobitz I is by far the most common form! 
NOTE: I've marked those P waves in the lower panel of Figure-4 that do not appear to have reasonable opportunity to conduct with WHITE arrows (ie, each of these 4 WHITE arrow P waves occur too close to neighboring QRS complexes to allow reasonable opportunity to conduct).
  • Looking at the remaining RED arrow P waves in the lower panel — We never see 2 consecutive RED arrow P waves occurring within any given R-R interval. As a result — we never clearly demonstrate that P waves fail to conduct despite being given adequate opportunity to do so ==> high-grade 2nd-degree AV block is not present.
  • Instead — What we see in the lower panel in Figure-4, are constantly changing PR and R-R intervals throughout the entire rhythm strip (ie, We never see the repetitive R-R intervals that we'd expect to see if there were a series of underlying junctional escape beats).
 ============================ 

Putting It All Together ...
The tracing in Figure-4 manifests an irregular supraventricular ( = narrow complex) rhythm in which there is an underlying sinus arrhythmia at an average rate of ~60/minute. 
  • There are more P waves than QRS complexes — which tells us that some of the on-time sinus P waves are not conducting (ie, that there is some form of 2nd-degree AV block).
  • The “good news” — is that the average ventricular rate is reasonable (about 60/minute), the patient is hemodynamically stable — and there is no evidence of high-grade AV block.
  • Despite the unusual finding of constantly varying PR and R-R intervals throughout this tracing — the most common form of 2nd-degree AV block by far is some form of Mobitz I, especially given that the QRS complex is narrow!
I propose the laddergram in Figure-5 as illustration of the probable mechanism in today's arrhythmia. Although some of the PR intervals that appear to be conducting are extremely long — this laddergram is consistent with 2nd-degree AV block, Mobitz Type I with 3:2 and 4:3 AV conduction.
  • Since the average ventricular rate is ~60/minute, and the patient is hemodynamically stable without evidence of high-grade AV block and without sign of any acute ischemic changes on her 12-lead ECG — I would approve this patient for undergoing her orthopedic procedure. As per routine — the patient will be monitored throughout her operative procedure to ensure no excessive bradycardia (though the risk for intra-operative arrhythmia problems would seem to be small).
  • Permanent pacing after her operation may not necessarily be needed (A longer period of Holter monitoring can be undertaken after surgery to ensure low risk of developing complete AV block).

Figure-5: My proposed laddergram for today's arrhythmia.


============================  

Final Note …
In ECG Blog #61 — I reviewed the fascinating case of a patient with vagotonic block. As discussed in that blog post — it is because of intense vagal tone (ie, from vomiting, pain, exertion, some procedure) — that surprising variability in PR and R-R intervals, as well as various forms of AV block may develop. On occasion, this array of unusual and unpredictable arrhythmia elements may develop without any known source of excessive vagal stimulation.
  • As discussed in Blog #61 — the literature is scant regarding vagotonic AV block. This unusual conduction disturbance occurs far less often than other forms of AV block — which may in part account for the difficulty in recognizing it. The disorder may be seen in otherwise healthy adults during normal sleep (especially in individuals with sleep apnea). Fortunately — the prognosis tends to be benign, and permanent pacing is usually not needed.
  • My Theory: The most logical explanation for the unusual arrhythmia features seen in today’s case — are that this older woman with known coronary disease and potential LPHB on ECG — is most likely manifesting sinus arrhythmia with an atypical form of Mobitz I 2nd-degree AV block that results from unpredictable variability in underlying vagal tone.

  • Addendum (11/14/2026): This tracing was sent to me. Unfortunately — my follow-up on this case is limited. I suggested that approval for elective surgery was reasonable given longstanding asymptomatic status, the likelihood of Mobitz I from vagotonic block — and knowing routine monitoring during surgery would be done in the unlikely event that bradycardia developed. I also strongly recommended 24-48 hour Holter monitoring post-surgery to ensure that bradycardia did not develop.

==================================
Acknowledgment: My appreciation to M Athar Sadiq (from Muscat, Oman) for the case and this tracing.
==================================